电话:13911250791
QQ/Wechat:fjstore
电子邮件:wliu@raid.com.cn
-
Broadcom 96系列修复固件 2025-02-08 **********************************************
Broadcom Avenger Firmware Release
**********************************************
Release date: 01/28/25
======================
Supported Controller:
======================Avenger 9600-16e
Avenger 9600-8i8e
Avenger 9600-16i
Avenger 9600-24i
Avenger 9600w-16e
Avenger 9620-16i
Avenger 9660-16i
Avenger 9670W-16i
Avenger 9670-24iComponent:
=========
Firmware Release for Avenger ControllersVersion Numbers:
===============
Current Package Details:
Firmware Package - 8.12.1.0-00000-00003
Firmware - 8.12.1.0-00000-00003
UEFI HII Driver - 08.12.04.00
UEFI BSD Driver - 0x080C0400
VisionFW - 25953.1C00_05877.0A00Previous Package Details:
Firmware Package - 8.11.1.0-00000-00003
Firmware - 8.11.1.0-00000-00003
UEFI HII Driver - 08.11.10.00
UEFI BSD Driver - 0x080B0900
VisionFW - 25953.1C00_05877.0A00Release Advisory:
===========================
Release Advisory: Event string update for event code BOOT_LDS_OFFLINE, BOOT_LDS_MISSING, and BOOT_LDS_MISSING_SPANSRelease Advisory: An online firmware downgrade from 8.7 (or later) to 8.3 or older is not supported. To downgrade to 8.3 or older from 8.7 (or later) will require either an offline activation with a power on reset or a two step downgrade from 8.7 to 8.4 and then to 8.3 or older. If an online activation or offline with a warm reboot is attempted, the FMC will fault with a boot chain mismatch. ER DCSG01546672 changes (Implementing patrol read operation CurrentCycle and LastCycle bit as persistent NVRAM entry) will have a behavior impact for output when the FW is upgraded/downgraded to the version which has this ER changes from any prior release.
Release Advisory: The patrol read show command will be effectively reset and display None for both fields, as below: PR Cycle completed PDs before the last clear None PR Cycle completed PDs since the last clear None Event string update for event code BOOT_LDS_OFFLINE, BOOT_LDS_MISSING, and BOOT_LDS_MISSING_SPANS - This issue is limited/observed only on systems with virtual enclosures. - Upgrading the configuration from 8.x (older releases) to 8.8 firmware and later downgrading it back to 8.x (older releases) firmware is causing Enclosure device ID and Physical Disk persistent ID to change. - Issue is also seen if one updates the firmware from 8.8 to any future build with Defect DCSG01586204 changes (ER-DCSG01201772 changes partially reverted). - The issue is observed because for Virtual enclosures in 8.7 & older releases the PhyBits were set to 0x0 and later in 8.8 as a part of ER-DCSG01201772 they were updated based on the PhyBits data provided by the PL. - In order to avoid the issue 1) One can do a cold boot on flashing the FW 2) Clear the controller persistent table. This can be done by issuing the below command in the CLI. - "devprstClear" - If the build is 8.8 & newer - "iop call devprstiPersistentTableClear" - If the build is 8.x (older releases)
Release Advisory: Vision Firmware upgrade process: - Provide the 'activationtype' option to storcli viz.: > storcli2 /c0 download file= activationtype=offline - When this command completes successfully, the following message will be displayed: ""A Complete Reset is required to activate Component Images."" - The next step is to restart the Host PC. (warm reboot) - Wait at least 5 minutes after the OS boots or attempts to boot. - To activate the new image, a full AC power cycle is now required for eHBA cards. For RAID cards, a DC power cycle is sufficient
Bug Fixes and Enhancements:
===========================FIRMWARE
DCSG01667277 Inline hashing IOP test application coding - part 2
DCSG01740581 Add ATA passthrough protocol support for NCQ
DCSG01762443 SMM: Reduce SMM Debug print level
DCSG01767041 FAULT 265D
DCSG01768710 FIPS compliance info is not reported when proper drive is locked after soft reset
DCSG01773468 Non Importable Drives tables (locked drives) do not show foreign/display "F"
DCSG01731324 Ctrl Diag hitting fault due to incorrect lmid data received from DMA
DCSG01727673 Firmware activation is not being failed while Online Capacity Expansion is in progress after acquiring the command block
DCSG01771904 SMM: Update to use wolf 05.07.02 with new custom defines
DCSG01759768 Task management timeout while running IOs+multiple outstanding TMs
DCSG01753494 Controller reports nvcache failure after updating the OEM firmware to 12.3
DCSG01760280 Windows os is not booting up with driver-8.11.09.00 and the latest firmware
DCSG01755013 Drive firmware download resulted in firmware fault 0x842a
DCSG01794386 BAD PRP2 entries during creation of volume
DCSG01773870 Fault 265c during policy change of RAID level with Task Management, IOs and other operations in parallel.
DCSG01722831 96xx Series: Allowing the SCSI commands from Host and OOB
DCSG01730919 Fault 265d while running IO Task management exception
DCSG01840943 SPDM export certificate operation not working for non provisioned slot 0
DCSG01835447 The hardware present bit remains unchanged even after the energy pack is removed during runtime.
DCSG01704633 9800 series controller initial FPGA bringup changes
DCSG01768428 Fault 0xC011 seen when running both Initiator and Target mode on same controller
DCSG01738473 Implement SCSI to NVMe Translation Layer specification version 1.15
DCSG01767098 Data Abort Fault while deleting Online capacity expansion and drive pull
DCSG01756554 Unlocked secure foreign drive becomes failed configured locked secure drive during soft reset
DCSG01813419 ASSERT: Fault Code 0x8b18 SSys 0xa Data Unhandled Cache Update error
DCSG01754235 Fix BSP max image size check in FMC
DCSG01663666 [9700 series] Potential DMA errors or data corruption due to multi row dissociated IOs during logical drive task management
DCSG01642432 Ring buffer decoder enhancements
DCSG01822907 PLDM Type 2 - Present sensor reading value is displayed incorrectly for sensor events in firmware trace
DCSG01728233 Inline hashing checkin bringup code changes
DCSG01723702 Update SerDes code and SBR to address a PCIe loopback issue
DCSG01752956 Fix signImageX menu and print
DCSG01769741 Data corruption in unaligned IO profile in 9700 series
DCSG01823493 Windows BSOD during random ECC test
DCSG01816951 NVMe: format/namespace recovery always fails
DCSG01770117 [9700 series] Command hang due to background operations on Logical Drive not pausing
DCSG01684939 Changes are made to disable the peroformance monitor support for non exixtent hardware blocks in Av 2c
DCSG01756765 Fault 8402 with buffered IO and online capacity expansion on logical drive
DCSG01562422 98xx: TLR target mode XRDY retransmit
DCSG01673247 Add inline hashing config page to xsd
DCSG01751180 Modify New Product Task Management to account for missing hardware blocks
DCSG01765175 9700 Series: Advanced Host physical drive created from third party secured drive is not exposed to operating system
DCSG01704639 Firmware: add manufacturing pages Programming capability to ScrutinyCLI
DCSG01841949 Set certificate command error data is not correct when forced an error by a write to slot 0.
DCSG01731015 Firmware hit fault while running task management on R5
DCSG01749397 9700 B0: Write DLC state for Recertified DLC
DCSG01710332 Update supported Host Interface Profiles
DCSG01771141 Add shutdown process to defer queue when ddf update in progress to avoid the deadlock for ddf update
DCSG01751404 9700 Series: Wrong Correctable error reporting enabled bit is reported to host in DCR register
DCSG01726236 Change the gPtrRaidTmDmNotificationDevHandleBmp from global to stack
DCSG01670931 Add NVDATA infrastructure for 9705 series controllers
DCSG01745915 97XX_OOB: SMM module failed to generate random data for encyrpted messages due to unaligned address
DCSG01746892 PTRACE: Fix calculation of RemainingTime and Remaining Buffer in PDIPage2
DCSG01767976 Update the Hardware Consumer index when buf get freed and use bufId in Firmware tracker for dump to avoid the infinite loop
DCSG01687924 Add Infrastructure for Hardware Workarounds for New Product
DCSG01764565 Fault 88BE during IO with Medium error, task management and drive pull with non parity raid config
DCSG01775712 Fault 0x1901 during function level reset and task management
DCSG01749886 97xx B0 Track : Recursive prints when diag check command pending while reset performed.
DCSG01749541 Add UART command to enable/disable micro write journal which will be utilized by Micro Offload BST
DCSG01764287 [9700 series] Command Block hang due to Region Lock submitted IOs
DCSG01751193 Add ECDSA support in SMM
DCSG01760767 9700 Series : Controller fault E41B observed while running Message Unit Reset test in eHBA Multi-Function mode
DCSG01772012 FPGA: Firmware Fault 0x8108 after Power on Reset
DCSG01649220 Changes to pull in latest hardware headers and make changes based on that for various structure fields relevant to AV 2c
DCSG01704643 Add low level support for VPD programming in ScrutinyCLI
DCSG01772412 Improve future product feature for handling multiple errors on same IO request
DCSG01776368 Fault 256D while running Device Missing Delay+key-Rekey and background operations TR:DCSG01758458
DCSG01734625 Start stop command leading to multiple drive resets with 9600 HBA firmware
DCSG01762102 Add support for UA (6/3F/16)
DCSG01765687 Keep a global bitmap for active FLR bitmap so the FLR event can be logged
DCSG01702887 Update the build process to support post-quantum signing
DCSG01782739 Series 9700: fix multiple print statements
DCSG01686339 Add a debug uart command to clear the physical drive persistent table.
DCSG01714341 SBLIB: CNSA 2.0 changes (ML-DSA-87, Dual Signature authentication, with single A0-B0 image support)
DCSG01760788 Clear cache enterprise key management across warm boot for RAID controllers
DCSG01757331 DDR training utilizing default SPD.
DCSG01742357 [9700 series] Device IOs should always be found in Lmid search
DCSG01655799 SignImageX: Sign image using LMS algorithm - Non-production HSM
DCSG01759871 Code analysis tool issue
DCSG01811207 Assertion failure in ..\src\p dSec.c line 1177 fault Code 0x8b0f SSys 0xa Data; observed while Secure physical drive removal when heavy IOs in place
DCSG01767697 9700 Series: 'third party locked' drive going to secured by megaraid after multiple resets
DCSG01839494 Set certificate command error data is not correct when forced an error by a write to slot 0.
DCSG01764162 Dev defect to port task management CSET from 8.11 to 8.12
DCSG01809393 SPDM error code data is not populated for error cases
DCSG01715129 Add ECDSA support in secure boot library
DCSG01743651 Modifications to External Key Management status check for certain operations
DCSG01745019 9700+ Series : Update code to take ETP ring buffer mask value from NVData
DCSG01767132 Firmware error during rebuild and logical drive property update + background operations
DCSG01733071 ECC errors in the IRC have crossed the warning threshold during IO on R0 and R5
DCSG01659175 Improved RAID Firmware handling of write same journal persistence across resets
DCSG01774161 Remove interactive means for both "pciePERSTOverride" and "pcieRefClkOverride from applications
DCSG01770393 Snapdump does not generate an MCU and energy pack summary
DCSG01745589 Review the PL/eHBA owned NVDATA pages for 9761W-32i
DCSG01757637 Developer Testing Serial Cache Offload BST
DCSG01753719 Remove the NAA(3) override in SAS address of NVMe device
DCSG01745591 97xx series: The drive list in an eHBA multi-function configuration is truncated
DCSG01755062 start stop unit command aborted if issued after download microcode command mode E with invalid image.
DCSG01766272 Firmware faulted with 0x84CB when copyback is stopped
DCSG01599598 98xx, ETP changes
DCSG01749017 MegaRaid Firmware: non-useful TTY log prints are dumped when sending Foreign scan and timeout DCMD
DCSG01753453 Offload Wrapper Header Update
DCSG01808409 Target mode driver stops receiving hard reset
DCSG01765331 Drives dropping/removed from host running soft resets in multi function config
DCSG01755112 Controller faults with 1937-e during task management
DCSG01743377 Multiple fixes for future product feature
DCSG01817735 Changes are made to remove unnecessary debug print which is misleading in case the Diagnostic buffer upload doesn't actually happen
DCSG01751604 deferred queue handling of raidShutDownProcess to avoid the potential admin queue not pull issue
DCSG01819284 FAULT 8406 observed while discarding PinnedCache
DCSG01774765 Controllers faults with code 0x84c8 while replace drive completes and deleting Virtual Disks
DCSG01737808 SB Lib changes for A0 (SMM/FMC/CBB): Clean up bringup temp cod
DCSG01773410 9700 Series: firmware assert is noticed when 'third party lock' is performed on the drive using debug interface
DCSG01740091 Make MR8_DCMD_PD_INFO_GET buffer[8] a non-blocking call
DCSG01692107 Evaluate existing hardware workarounds for applicability to New Product
DCSG01764527 [9700 series] Data corruption during logical drive task management
DCSG01749040 Tool detected Issue
DCSG01773134 Ensure correct error reply for MPI toolbox requests by non-supervisor functions
DCSG01769859 Fix defect found with Static analysis tool
DCSG01743999 [9700 series] Fault when IO in scope of Abort Task is re-issued by the host before Abort Task completion
DCSG01749420 PTRACE: Component changes for added IALx message
DCSG01769084 Firmware fault during mode select and task management
DCSG01649349 Update SAS Core count defines to be derived better
DCSG01689160 Firmware assertion mem.c at line 897 while running IO on 240 R0 logical drive and online control reset every 3 minutes
DCSG01771602 firmware fault during host IO on JBOD NVMe config
DCSG01745977 97xx: host side PCIe completion time limit may not be configured properly
DCSG01769121 [9700 series] Command Block hang due to IOs stuck in Buffer Manager
DCSG01771869 SBLIB: Add Wolf defines for ML-DSA-87 validation
DCSG01729352 FPGA Target mode integration with IO Generation Tool
DCSG01766949 Code Analysis tool found issue
DCSG01760043 Add dual signature support for ECDSA and MLDSA-87
DCSG01770065 Storcli2 hung observed after issuing MUR
DCSG01814428 SPDM error code data is not populated for error cases
DCSG01740610 Add Task Management LMid to PL Task ManagementHistory Log
DCSG01761282 Update code comment in Link Quality Monitor code
DCSG01731258 Series 9700: Firmware hang on Snapdump creation while injecting 0x88F3 faults
DCSG01710447 Update SMM load address for 97xx boards
DCSG01754263 NVMe: Firmware faults with Fault Code 0xE405 when running IO stress and Task Managements to NVMe drives.
DCSG01744752 Series 9700: Remove the A15 enabling Hardware generate PFNotify for Soft Reset
DCSG01764273 Fault 8B17:gen4fw\raid\src\raidFwMain.c followed by 8960:gen4fw\raid\src\mrInterface.c. seen and the controller goes into loop and non recoverable
DCSG01742843 Target Mode Abort for an Initiator
DCSG01745884 The sanitize operation does not complete when a reset happens in middle of the operation.
DCSG01614588 Implement SBR for New Product
DCSG01798720 Fault 0x26AD observed while controller reset with rebuild and PLDM type 0 in loop
DCSG01751688 Series 9600+: Update workaround for TxFM Non-Auto Timeout
DCSG01753828 PEX 89000: Mismatch in the PTrace Summary fields (Capture Time and Data) between Inband, UART and SDB Mode of discovery
DCSG01756637 Cleaning up dead code in Backup energy Module to increase the overall code coverage
DCSG01611701 (NVMe Only): Add support for NVMe 2.0 drives
DCSG01757640 Fault 6D0B seen during IO-Task management test on future product feature
DCSG01754809 97xx NVDATA ManPage 7 number of receptacles not correct for 16i and SAS queue depth on eHBA not matching Raid.
DCSG01817037 Rebuild did not kick in when import a Physical Disk member into degraded Virtual Disk(that was previously marked as 'Offline')
DCSG01804364 9700 Series+ : Disable LTR and OBFF support
DCSG01773041 New internal APIs to provide access control to writing MPB content for relevant config pages
DCSG01692108 New product support for additional hardware cores
DCSG01808853 Adapter Reset due to Command Block Stuck
DCSG01750268 Warm reset is happening when restoring pinned stream.
DCSG01752718 Add support for greater granularity in blocking advanced error reporting prints using debug mask.
DCSG01770150 Fault 0x8b32 with IO and virtual drive cache policy change using mode select command
DCSG01772740 Fault observed while running stress IO task management test.
DCSG01754970 Dev defect found during code review
DCSG01730913 Hitting FAULT:0x88ce
DCSG01723263 SignImageX changes to support ECDSA
DCSG01757819 9700 series: storcli2 failed to display "Physical Disk allowed map Information" after deleting existing drive mapping
DCSG01756548 A0 Static Tool Analysis
DCSG01774077 Series 9700: Recursive FAULT 265d Instance 1 Cpu 0 while generating snap dump for f007 fault
DCSG01765853 ASSERT: Fault Code 0x89f4 SSys 0xa Data cbReq 82ad25c4 should be in Execution State
DCSG01751240 97xx: EC7C fault during backend PCIe link resets
DCSG01753656 Ref Clock not enabled when backplane detection fails
DCSG01634447 Support added to configure the hardware debug memory for the hardware trace
DCSG01760323 Fault 265D while deleting preservedcache on alternate Logical drive.
DCSG01810981 PCIe IO Unit Page 0 may return random data in EnumerationStatus field on PCIe disabled phys
DCSG01770899 Fault 8A19 observed when delete parity volume 6 with IO after completion of online capacity expansion
DCSG01715663 Miscellaneous fixes for the host driver bring up on the FPGA
DCSG01679146 Copyback operation suspension command should have checks for pair physical drives before proceeding for operation
DCSG01611027 Verify ability to enable/disable SAS PHYs
DCSG01769762 During insert/reboot, reporting of a faulty enclosure for No Access Allowed Drive
DCSG01710816 Changes are made to fix the access of gIopSwEventState array
DCSG01753748 Incorporate CPLD version X02 and MCU version X07 for OEM controller firmware
DCSG01744930 FAULT F000 Diag Fault Reason Code: Dw0:20000001 Dw1:00000000 when running Online Capacity Expansion and rebuild on parity volumes with unaligned IO
DCSG01703289 Add additional hardware task ring IDs for additional hardware on future product
DCSG01759706 Updating SAS Gen4 optical cable TX parameters
DCSG01822233 Firmware does not log 'exited safe mode' event after discarding pinned cache
DCSG01728976 Code review defects
DCSG01777339 Improvements for handling micro write journal after being disabled by NVDATA (Manu page 40)
DCSG01742104 Series 9600+: Ensure that all structures in global ETP_GLOBAL_INFO are aligned
DCSG01650605 Update some compile option defines for future product/feature
DCSG01591522 Power down the hashing hardware for solutions that don't support it
DCSG01773892 Firmware fault 8402 while background operations on logical volumes
DCSG01772810 [9700 series] Firmware fault when backend IO under medium error is aborted due to task management
DCSG01736626 [9700 series] IO timeout resulting in diag fault reset due to low RSGLs
DCSG01772248 ONFI LED6 blinks during BGI operation
DCSG01831586 BMC Emulator is able to overwrite slot 0 after creating a secure session.
DCSG01694259 Enable TLR ring buffer prints
DCSG01827431 singleDriveR0unmapWithRA, singleDriveR0wsunmapWithRA needs to be set to true
DCSG01816808 Disable Report Zone host IOMMU support version by default
DCSG01823668 Automated testing is not collecting the correct snapdump nor clearing old snapdumps
DCSG01758418 Fault 0x060D while running IO and task management and Function level reset
DCSG01751621 stored value is overwritten before it can be used.
DCSG01765742 Remove the backdoor that allows setting the host interface profile to any values
DCSG01744826 FAULT:f000 after completion of Online Capacity Expansion with medium errors
DCSG01765063 Re-order checks during reprovision to have allowed ops check first
DCSG01615070 Made changes to make the maximum transfer size of 8 MB for various modes for AV 2c
DCSG01562426 98xx, Added Target mode response frame transport layer retry
DCSG01740312 9700 series: Fault 0x6207 observed
DCSG01713213 Use dynamic spdm configuration parameters instead of compile time values and add support for set certificate request
DCSG01812801 Error message which indicates failed to generate the event though the event is generated successfully
DCSG01809315 Fault while deleting volume
DCSG01744340 ASSERT: DevId ffff is not valid
DCSG01331954 Firmware fault 0x8B3E
DCSG01808478 Updated IO Unit Page 13 page attributes at runtime
DCSG01718393 Support up to 8 physical functions for 9705 HBAs
DCSG01736887 Update Drive Capabilities After Drive firmware Update
DCSG01472477 Modify global fault led GPIO behavior when in internal test mode.
DCSG01767980 A0 FPGA: With 8.11 firmware it is faulting with "iopFmcFault : Fault Code 0x00000035"
DCSG01754937 9700 Series: Ruby drives doesn't get detected as 'third party locked' after setting it on a JBOD and converting to unconfigured good state,
DCSG01767643 0xF000 fault when running background operations and delete volume operation
DCSG01757187 Fault 6A1F seen during IO-Task Management test on FPGA
DCSG01735959 cleaned TEMP_CHANGES_A0_BRINGUP - Following instance removal
DCSG01804630 Expander firmware update fails when the controller is booted in safemode while having topology error
DCSG01835423 PEX89000: firmware allows the BMC to overwrite slot 0 after creating a secure session.
DCSG01766572 Inline hashing validation tool bringup
DCSG01768644 Firmware fails to log Driver load event following a FLR
DCSG01745216 Add the support for RAID/IOP : MF - OS Device Ordering
DCSG01796155 Enable AVL Optimization by default
DCSG01773905 Added a new command response code for target device shutdown
DCSG01751101 Series 9700: Controller failed to fault when installed on insufficient power pcie slot
DCSG01745952 97xx series: Using the UEFI bios utility to access drive information results in errors.
DCSG01714351 SignImageX: Add ML-DSA-87 signature checks
DCSG01652096 TLR Target mode skip count
DCSG01770003 Energy pack Current, charging current, and relative state of charge information values are 0
DCSG01749390 97xx : Remove support for obsolete PSoC registers regarding PSoC logging
DCSG01775793 Suppress device discovery in core BSD as per OEM request
DCSG01772917 Use dynamic spdm configuration parameters instead of compile time values.
DCSG01815795 FAULT: F000 while deleting the Write Same Virtual Drive during IOs are in progress
DCSG01744285 Firmware fault during Online Capacity Expansion Abort with Pinned Cache generated while Online Capacity Expansion is in progress
DCSG01711092 Enable approved environment variable customization for customer releases
DCSG01670304 Host messaging unit and Host interface layer changes for 9705 series controllers.
DCSG01728071 9700 performance tuning changes
DCSG01761693 9700 series: TMD - F000 Fault RC:FF while running IO + TMs in Target mode
DCSG01599734 NVMe: VSL handling for the Verify translation
DCSG01757203 IO Error during Simultaneous Task Management on Target-Mode Custom Config
DCSG01666043 Add run-time support in CDU Unstall code to bypass specific message frame stall conditions.
DCSG01809263 Changes are made to make sure earlier reset action field value is cleared off just before the diag progress bit is cleared.
DCSG01812582 Replace error title to warning when requests are retried
DCSG01782565 Storcli2 hung observed after issuing MUR
DCSG01774582 Fault 88BE during IO and task management with media errors
DCSG01772023 Fault 87f4 durint IO and taskmanagement
DCSG01773559 Escrow Timer Causing Escrow Keys to be Deleted Even During Drive Unlock
DCSG01755058 MegaRAID Firmware: DDF Debuggability improvements
DCSG01751523 97xx : Relearn operation is completed twice during Auto Learn or First time a new version of PSoC Firmware is started
DCSG01761479 Firmware faults when write policy is changed through mode select from host
DCSG01815844 Fault 6A1F seen during long running IO Stress & Taskmanagement test
DCSG01589882 Series 9600, 9700: Adjust NVData and IOCFacts for no transitioning of Driver Diagnostic Buffers
DCSG01711883 9800 series controller FPGA bringup improvements
DCSG01727434 Handle DMA Errors for Online Capacity Expansion IOs during Physical Function shutdown
DCSG01613723 Added debug API to change the CPU frequency on a fly based on the low speed mode (LSM bit in CCR System PLL Clock Control register) programming.
DCSG01735888 Series 9600+: New firmware faults with watchdog timeout instead of set slot power failure
DCSG01760235 Firmware fault during policy switch
DCSG01748811 Invalid parameter error observed while discarding preserved cache in HII
DCSG01817746 Cryptographic erase is allowed to issued on logical drives
DCSG01736049 Event is not sent during reset
DCSG01723602 Generation of a Unique ID for SATA drives in eHBA Multi Function
DCSG01820853 96xx Cache Offload BST: Controller not found error after reboot
DCSG01768964 FrameReqPending: MidType 3 Before Inc:Val 10000 prints seen in UART continuously while running unaligned stress test
DCSG01760305 Fault 0x8932 while running Online Capacity Expansion with Medium Error on NVMe drives with Target Reset on Logical Drive
DCSG01644407 For 98xx implemented xfer_rdy target mode TLR handling, code is disabled by default.
DCSG01772943 FAULT 265D ERROR! Exception during IO, Task Management, rebuild in loop along with media error and online capacity trigger
DCSG01678156 98xx: ETP FPGA specific code change
DCSG01763209 PKA_QLIP: Add build files
DCSG01766847 Component changes for versioning changes.
DCSG01809903 Fault 6A1F seen during IO Stress & Taskmanagement test
DCSG01749687 [9700 series] Physical Drives being failed due to internal backend IO RetryCount exhaustion during host logical drive task management
DCSG01697658 Change build process to support BSTs on customer boards
DCSG01749391 FIPS compliance information is not reported on SAS HDD SED drives
DCSG01749645 Modify hardware workaround when pausing SASCore DMA Engine
DCSG01690920 Add power control for future product hardware cores
DCSG01766123 Controller should block delete security key operation when native locked drives are present even for key exchange failure.
DCSG01673191 Inline hashing additional changes
DCSG01814252 96xx MSS: DDR failure (G-die)
DCSG01763858 SPDM - Allow SPDM 1.2 requester's to send multiple opaque versions during key exchange
DCSG01833931 LogPelEventHostReadFailOnLdBBMEntry bit says its only for internal verification
DCSG01721399 98xx set PCIe device class code as SCSI controller
DCSG01773827 [9700 series] Firmware Fault due to Dissociated IOs with no child Accelerated IOs being held in Multi Row Dissociation List
DCSG01753995 ASSERT: 0x89F4
DCSG01809290 When there is no certificate on a slot, issuing get cert command on it is giving wrong error.
DCSG01709540 Remove serdes debug data from PL dump
DCSG01753624 Hashing SGE doesnt match hardware spec
DCSG01726229 Series 9600+: Add iop mpi iounitctl ranges
DCSG01611878 Improve comments for hardware block disablement feature
DCSG01752720 Snapdump DCMD properties returns inconsistent response for unmodifiable properties
DCSG01611197 Support up to four MPI physical functions
DCSG01767887 Integrate MCU 0x0B version image for OEM controller
DCSG01734522 Assert in DMA manager code module when running I/O to NVMe drives
DCSG01736630 IOMMU Fault reported for 97xx card
DCSG01757708 Firmware does not clear internally cached shadow registers when host side correctable error is cleared on a multi function cofiguration
DCSG01752653 Integrate MPI3 Interim headers
DCSG01750779 Firmware fault 6013 observed with IO and Task Managements
DCSG01766866 9700 series: Drives mapped to Non-Supervisor Physical Functions failed to rediscover drives after expander powercycle
DCSG01733186 Add hardware debug memory (HDM) as a new destination for the hardware trace buffer.
DCSG01611691 Firmware support for SCSI NVMe Translation Layer Specification version 1.14
DCSG01835419 Dirty Hash Slot Elements May Not be Evicted
DCSG01820369 97xx: Cache offload failed during BST
DCSG01743074 Fault 265c during Online capacity expansion of RAID level with Task Management and IOs
DCSG01684499 FPGA specific Host messaging unit and Host interface layer changes for 9705 series controllers.
DCSG01745585 FaultCode 0x89f0 seen when a command is issued to check the LED status to SAS Enclosure SES/Bad NVMe drive
DCSG01756998 Various minor fixes for future feature, mostly UART print removals
DCSG01703758 Various changes for new product emulation bringup
DCSG01819042 96xx: Code asserts with 0x89f0 fault when freeing memory allocated for a read retry descriptor
DCSG01073479 Remove obsolete debug command line interface commands
DCSG01758237 ASSERT: Fault Code 0x8a02 Inhibit flush count is not set
DCSG01773953 Use Fis type instead of Array for translating NCQ ATA passthrough commands
DCSG01693665 97xx Cache offload BST - Script write/modification part II- added Battery Energy Management BST scripts
DCSG01771156 Non success response needs handled in case of new feature
DCSG01771825 WolfSSL: Update to version 05.07.02 and add custom defines
DCSG01740036 Inconsistency between data being displayed by applications
DCSG01752328 Storcli2 /c0/pfall shows the incorrect PCI-Info information
DCSG01839654 SPDM export certificate operation not working for non provisioned slot 0.
DCSG01774910 Fault 0x8400 during IO and task managements on virtual drives with unrecoverable medium errors
DCSG01818359 MR8_EVT_CTRL_NOT_ENOUGH_MEMORY is being generated incorrectly when running diagnostics on EVP controller
DCSG01776553 IOC failed shutdown observed while running MUR test in eHBA Multi-Function mode
DCSG01693664 Cache Offload Parallel BST
DCSG01761193 Foreign secured locked drive is no longer marked foreign after escrow key is deleted
DCSG01758769 Code analysis Fixes
DCSG01766990 Firmware fault observed when running a negative test case of device missing delay less than required
DCSG01727593 F000 fault while running IOs and DCMDs in loop
DCSG01754498 Fault 0x6001 seen for Report zone commands with IO stress and exceptions
DCSG01748966 SPDM: set certificate operation does not write the chain on the correct slot
DCSG01754772 Add support to store certificate chain in the chain store under secure world
DCSG01762381 SignImageX: Fix byte count used to copy embedded public keys
DCSG01758885 Wait Queue pointer clean up crashes the firmware
DCSG01753173 API version update
DCSG01768967 Improve logging and debugging in multiple physical function environment
DCSG01759761 Firmware fault 1937/2 while testing multiple outstanding task managements on a device
DCSG01752470 9700 Series: Updated PEX PCIe tag setting
DCSG01819255 SignImageX: Pad the Encrypted Hash Extended Image for alignment and remove minimum size precheck
DCSG01765330 96xx Series: Controller not booting to safe mode after setting dbgBootEvt in eHBA personality
DCSG01771343 Integrate MPI 3.00.34 headers
DCSG01765614 0xF000 Fault due to SCSI Task Management Target Reset to an NVMe drive being incorrectly forced to hang.
DCSG01776556 Firmware download fails with latest release order
DCSG01713360 Future product bringup changes
DCSG01773966 Error Description is coming wrong when trying to import certificate without a session
DCSG01749020 Send Blink and Unblink to multiple drives in one request for Logical Drive Locate
DCSG01748784 Fault 1937 seen during IO and task management
DCSG01746415 Cache offload BST improvements
DCSG01815175 96xx : ECC errors are seen during Cache Offload Testing during BST
DCSG01744240 4K SSD drives discovered as OS disk in ESXi 9.0
DCSG01758358 Firmware is not clearing GPIO Interrupt raw status register while handling EPAK_ONLINE and ATTN_N interrupts occurred simultaneously
DCSG01736060 Firmware fault while policy change and copyback on logical volumes
DCSG01751057 Block Allocation/Deallocation Ring Buffer for NAND
DCSG01685668 Consider LUN field into account while deciding on the overlap conditions between task management requests
DCSG01816553 SPDM secure session not working with Mutual Authentication
DCSG01725066 Improvement in FLR handling
DCSG01756792 Fault 0x1937-13 seen with IO stress and Exceptions
DCSG01763828 Bug found by using static analysis tool
DCSG01732981 FAULT: 8936 occured when a foreign locked drive is unlocked
DCSG01745764 FAULT 1937 when running task management and IO along with Media errors
DCSG01763218 [9700 series] Command Block hang during firmware activation
DCSG01808573 Replace error title to warning when requests are retried
DCSG01766166 Translation of NVMe status code Namespace Not Ready is backwards in relationship to the DNR bit
DCSG01721646 Verify TLR Data out NAK support
DCSG01726087 In New Product Task Management, bypass the states that generate a Raid Manager flush request
DCSG01668698 Peripheral Bus Access Module and maximum Phys update for 9705 series controllers
DCSG01823898 Fault 6A1F Observed while running IO, Task Management and function level reset test
DCSG01815897 Assertion failure at ..\src\ModePageConfig.c line 225 faultcode 0x823a
DCSG01766999 Fault 8482 observed while running IOs followed by Function Level Reset on New Product.
DCSG01825865 97xx: Read-Retry issue observed when corrupting SOF on OEM NAND
DCSG01757123 Handle Logical drive Buffer Class Reconfigure for Dirty cache scenarios
DCSG01747214 [9700 series] NVMe JBOD first child failed/diverted Lmid shouldn't be accounted for in CDU Lmid search
DCSG01750304 Series 9700+: Add a feature to make writable pages show read only to NSPF's that cannot write them
DCSG01756865 9700 series: Assigning a SATA device to a non-supervisor function generates a 0x8934 fault
DCSG01740288 Series 9700: Snapdump ID and timestamps are not matching
DCSG01742265 Enable OEM Supercap MCU Integration and Support
DCSG01611254 Support and test Autodetect of Common Clock vs SRIS/SRNS on host side
DCSG01771614 97xx series Device Reporting Order is set as Logical drives are reported after JBOD devices
DCSG01761505 97xx A0: Running unaligned IO with medium errors and Online Capacity Expansion on RAID Level 6 Virtual Disk hits FAULT: EC64
DCSG01742184 Fault codes not unique
DCSG01757410 Firmware fault 6013 observed with simultaneous IO and Task Managements
DCSG01773311 Re-add ability to launch a local static analysis build.
DCSG01792305 Enable ECDSA support
DCSG01725561 Refine MUR Handling
DCSG01634504 9700 series: Copy existing traces to segmented host TB in RAID mode
DCSG01772364 The Firmware shall not reset the onDemandSnapDump capability bit while returning the SD properties to application over OOB.
DCSG01769301 Needs controller key AEN being generated when inserting foreign External Key Managed secured drives
DCSG01754701 RAID/IOP Parity Write Through Performance (FSW profiles) not hitting the max bandwidth
DCSG01775007 command block not granted under certain work load in 9700 series
DCSG01766475 Firmware fault when running IO along with other IOCTL commands
DCSG01672602 Inline hashing test scripts
DCSG01814275 96xx DDR4-3200 compliance - MSS_MC_FREQUENCY_SCALING_SUPPORT define
DCSG01746262 Snapdump not generated after a firmware assert
DCSG01765429 97xx: update eHBA NVMe and switch counts
DCSG01753167 The OOB Firmware will return a new OOB command response code if the IOP fail a mpi request with iStatus ISTATUS_SHUTDOWN_ACTIVE
DCSG01827959 For invalid value, snapdump validate function should return FALSE
DCSG01761683 97xx: disable NVMe SGL usage in eHBA mode
DCSG01763425 F000 fault occured while running storcli command in loop
DCSG01752584 Security key unlocked event missing when converting a secure JBOD to UCONF
DCSG01748893 Too many BVD related logs coming in the UART
DCSG01749373 96xx : Improve code coverage for Battery Energy Management
DCSG01773230 Pel event description is not correct for persistent ring buffer logging disabled event
DCSG01765369 [9700 series] Task management timeout when superceded while walking hardware pendlists
DCSG01714343 9700 CNSA2.0 (SMM): Add Dual Signature key update with ML-DSA-87 support
DCSG01744357 Multiple changes for future product feature
DCSG01702884 Update signImageX to handle ML-DSA-87 requests and dual signature (single image A0-B0 for 9700)
DCSG01753144 Firmware fault during Task management and IO stress
DCSG01766601 Micro Write Journal feature is disabled, but the EVT# 714 is getting generated which is not correct
DCSG01809458 NVMe: Namespace Not Ready during NVMe initialization with NVMe 2.0+ devices
DCSG01755387 Fix release build process for 98xx firmware
DCSG01774520 ASSERT hit after online capacity and task managements in progress
DCSG01771957 Update Target Mode Initiator overflow event to match MPI spec
DCSG01808777 Observed Fault=0xf000 with Diag Fault Reason Code: Dw0:10000006 Dw1:00000000
DCSG01756641 Bus Mastering error handling
DCSG01751672 Read OEM Supercap VPD data from MCU and populate Supercap design information
DCSG01690177 FPGA Additional serdes initialization
DCSG01745996 97xx A0: Device Manager context in-use assertion hit
DCSG01713215 96XX OOB: Add support for secured spdm message
DCSG01740574 Mechanism to update Backplane Components during Topology Errors
DCSG01751062 NVMe: diag command to set MDTS for testing
DCSG01814203 When there is no certificate on a slot, issuing get cert command on it is giving wrong error.
DCSG01769151 Fault 265D while deleting R5 Virtual Disks and drive pull
DCSG01753257 FAULT: 8841 ASSERT: File gen4fw\dma\src\dmaMgr.c line 1945 fault code 0x8841 SSys 0x16 Data AXI/ SGE error occured, recovery procedure not-implemented on drive pull and CLI show
DCSG01636570 PEA: Update firmware and hardware versioning and PEA Release process
DCSG01742830 Logical volume delete command timing out leading to diag fault reset
DCSG01696922 Inline hashing - sync with latest stream management commands spec
DCSG01752467 Optimize the flash writes done during SnapDump generation in eHBA mode
DCSG01772890 FAULT: E429 while running IO to NVMe drives and Pulling and pushing the drives
DCSG01749825 97xx series: F000 fault is observed when updating the firmware to version 8.12.0.32-01000-00002
DCSG01730929 Firmware faulted under heavy IO and drive removal testing
DCSG01808326 SPDM allow BMC to negotiate with additional certificate slots when populated
DCSG01752655 A couple of small improvements for New Product FPGA
DCSG01713583 Updating enablecopyback flag condition correctly for setting controller property
DCSG01753750 LSA hung while downloading Server Reports
DCSG01652024 Destructive Domain developer test script improvements
DCSG01761464 Fault :1937 during IO and Online Capacity Expansion on degraded Virtual Drive with Task management in parallel
DCSG01666843 Non SDK solution for exercising inline hashing - part 1
DCSG01752862 Added BST multifunction support
DCSG01758312 ASSERT: File gen4fw\raid\src\raidAvl.c line 553 Fault Code 0x8795 SSys 0xa Data Array tree info corrupted. ptrAri:0x81b52a60
DCSG01745783 Linter needs to ignore directories
DCSG01740567 Add new NVData parameter - TimeStampUpdate - to allow user tunability for Host-TimeStamp Sync
DCSG01753165 Improve handling of OOB MPI requests when the controller is in any shutdown mode and the driver is unloaded.
DCSG01761260 9700 B0: Check image key2 embedded key in the image
DCSG01769397 Firmware assert due to CDU Search found Lmids freed by hardware
DCSG01749023 Introduce a new field to convey that a drive is actually unlocked even though firmware treats the drive as locked.
DCSG01755302 96xx : Add UART command to test invalid temperature sensor
DCSG01777872 96xx Series: ATA passthrough command from oob path is failing
DCSG01743654 Continuous " hostintfAdminGetRequest IOC=3 ci=pi=17b" prints seen on UART while running IO stress to NVMe drives
DCSG01791338 Secure-Mode Firmware image validation failure
DCSG01770446 Predictive failure data is not updated in the Pdinfo API when the drive is in Unconfigured Bad state.
DCSG01706640 Implement Smm Assert functionality
DCSG01709290 SecureSign hangs cause BST timeouts or build hangs
DCSG01644398 98xx TLR target mode handle retry on data in frame
DCSG01721798 9800 series controller bringup - CFG and MPB checks
DCSG01752934 NVMe: add check to ensure that Abort aborted the targeted IO
DCSG01734476 [9700 series] Data abort exception due to re-entrant code resulting in stack corruption
DCSG01766380 FAULT: F000 while IO with drive pull-Push in a loop, seems "ccommand block Flush is stuck"
DCSG01644949 9700 series: Enable MPI segmented host trace buffer by default
DCSG01764550 Added changes to toggle the LED polarity for the global drive activity LED and also rectified the wide port programming
DCSG01744079 9700 Series: could not mark the drive 'third party secured'
DCSG01810482 96xx cache offload mss test scripts failing on OEM product cards
DCSG01750309 Firmware incorrectly increments the escrow try counter when the escrow key list is full
DCSG01777502 NVMe: API to obtain device ready time
DCSG01744336 Series 9700+: Eliminate shadow register and PMU register range accesses
DCSG01766935 Skip DL Inhibit count decrement for the sliced case if the sliced logical drive is not pinned
DCSG01743066 Consistent behavior for pass through commands
DCSG01811042 SPDM secure session not working with Mutual Authentication
DCSG01819883 apps set smartpollinterval command is not working on 9600-16i in feature IT profile
DCSG01767700 Add support to discard persistent TTY and RingBuffer after factory reset
DCSG01729807 Fault 0x8453 when running Online Capacity Expansion with IO and copyback
DCSG01769110 Fault 1937 During IO and Lun reset on Multiple logical drives
DCSG01705477 WOLF GIT: Add wolf dilithium (ML-DSA-87) to git
DCSG01766281 For an OEM match NVDATA parameter with channel
DCSG01761685 Online Capacity Expansion reports status as successful, even though no changes are made when free space left is less than strip size.
DCSG01559888 FPGA backend phys/cores handling
DCSG01813416 Task Elements exhausted while running medium error tests with write same IOs
DCSG01744226 96XX OOB: Add support for secured spdm message
DCSG01736474 Fault 8506 while freeing mid frame during task management
DCSG01757628 Series 9700+: Program Fault (0x2656) When SVC mode interrupt occurs
DCSG01775748 [9700 series] Firmware Fault due to Dissociated IOs with no child Accelerated IOs being held in Multi Row Dissociation List
DCSG01740776 Cache flush count increment after a cache restore is incorrect
DCSG01721648 Future product future feature dev testing and update
DCSG01769087 OOB Shim MR8: Debug ability improvements
DCSG01771097 97XX OOB:: Enable I2C[0] and OOB Stack bring up on FPGA
DCSG01809249 Logical disk policy change using sd pram in a loop is resulting in F000 fault
DCSG01711154 Test Expander SES on future product FPGA
DCSG01812565 Update WolfSSL git repo to wolf release files 5.7.4
DCSG01745846 Inline hashing test internal IO
DCSG01767356 MPI 3.0: Header file changes for MPI3 revision 34
DCSG01753800 96xx Series - Feature HBA - Some get ctrl property fields are not configurable from set controller property
DCSG01756354 Firmware should check whether Supercap is fully charged during Start of Day initialization , If not Firmware should allow Supercap to charge fully, poll for FC bit and wait for 60 seconds
DCSG01682273 Inline hashing IOP test application coding - part 3
DCSG01753164 RAID Firmware Handling of OOB Requests when Controller is in Shutdown State
DCSG01773002 Offload failed during pinned stream interruption
DCSG01715039 Pinned Stream is inadvertently discarded after warm/soft reset
DCSG01776570 Firmware crash with IO with large SGE in 9700 series
DCSG01742870 [9700 series] Race condition in Request Queue CI update for hardware workaround during HRU-CDU task management
DCSG01671026 Changes for compilation and linking SAS52xx
DCSG01661838 OOB_LIB: Debug ability improvements
DCSG01364639 Series 9700+: Incorporate an algorithm to allow reversion of bad host interface profiles
DCSG01733864 Harden error handling for TTY/RB Streaming and Snapdump Streaming
DCSG01760237 VirtualSES displayed as Faulty with incorrect SLOT details.
DCSG01808950 Fault 842A observed during database copy between R10 and R6 volumesUEFI BSD DRIVER
DCSG01803225 BSD: Fix BSD performance bottleneck in OEM system
DCSG01772962 Preboot_Utils: Make UEFI auto reboot message more generic to cover both RAID and HBA controllers - Request Backport to MR8.11UEFI HII DRIVER
DCSG01756920 HII: reduce calling of getting personality
DCSG01743689 HII: Items with the Help form
DCSG01703873 Preboot_Utils: Slot Element error NO access allowed should NOT make Enclosure "Faulty"
DCSG01803229 HII: Fix HII navigation performance bottleneck in OEM system
DCSG01814816 HII is using JBOD terminology for the Reconfigure feature instead of oem customization
DCSG01650847 Preboot_Utils: Enable StorCLI to Control SmartPolling
DCSG01749025 Preboot_Utils: Introduce a new field to convey that a drive is actually unlocked even though MegaRAID treats it as locked.
DCSG01761579 HII: handle MR8_QUERY_TYPE_LD_PRESERVED_CACHE failure case (MR8_DCMD_STAT_FW_INIT_NOT_COMPLETE)
DCSG01766121 Preboot_Utils: Modify failure message on snapdump generation for error code 0x8d
DCSG01771321 HII: redesign of "Select First Device" page in Perf-IT mode
DCSG01730994 Partial Persistent Events saved with HII
DCSG01710516 Preboot_Utils: 450W-16e Remove HII NVMe/PCIe items
DCSG01821674 An unexpected Error has Occurred when clicking on Manage SAS Storage Link Speed when controller is in Safe Mode
DCSG01799776 Preboot_Utils: HII to use DDR Memory Size and not Cache Memory Size - request backport to MR8.11
DCSG01776575 HII: change "Select First Device" suppress/readonly conditions
DCSG01742132 HII: Code analysis tool run -
Broadcom 9560-xx 52.29.0-5442固件 2024-05-05 ======================
Supported Controllers
==================MegaRAID SAS 9540-2M2
MegaRAID SAS 9540-8i
MegaRAID SAS 9560-8i
MegaRAID SAS 9560-16i
MegaRAID SAS 9580-8i8e
MegaRAID SAS 9562-16iComponent:
==========
Release Date:
05/02/2024Version Numbers:
================
Current Package Details:
Firmware Package: 52.29.0-5442 (MR 7.29)
Firmware 5.290.00-3997
MR PL 29.250.01.00
MR CBB / NVDATA / SBR / BootCode package 5.2900.00-0761
SBR_RMC 490
BIOS package 7.29.00.0_0x071D0000_07.29.00.00
UEFI_Driver 0x071D0000 (SIGNED)
Legacy BIOS 7.29.00.0
Hii 07.29.00.00 (SIGNED)Previous Package Details:
Firmware Package: 52.28.0-5305 (MR 7.28)
Firmware 5.280.00-3972
MR PL 29.25.01.00
MR CBB / NVDATA / SBR / BootCode package 5.2800.00-0752
SBR_RMC 490
BIOS package 7.28.00.0_0x071C0000_07.28.04.00
UEFI_Driver 0x071C0000 (SIGNED)
Legacy BIOS 7.28.00.0
Hii 07.28.04.00 (SIGNED)
Bug Fixes/Enhancements:
=======================DCSG01516158 Incorrect License Options
DCSG01537426 3808N: Power customization for Generic and OEM specific profiles
DCSG01496873 PL Firmware : SAS Phy Page 0 is not showing correct values when vses disabled
DCSG01512673 Turn Off Clock for CPU 1
DCSG01507280 Fix the performance drop due to code change
DCSG01506471 7.27 PA1 - 3808N: cant set ctrl properties via storcli
DCSG01460317 BMC reset in a loop leads to controller not being detected through MCTP over I2C
DCSG01400120 Add PERST control for NVMe drives
DCSG01510133 Constant add/delete of R0 and then power off enclosure causes data abort
DCSG01550785 Invalid Enclosure ID was observed when NVMe drive was hotplugged to 9580 card
DCSG01488049 PL Fault During IO and Driver Load/Unload
DCSG01488430 Add Firmware Version 28 for PartNumber 15987 to PSoC Catalog Image
DCSG01546839 Read(32) or Write(32) CDB sent to NVMe drive reported incorrect additional sense code
DCSG01520805 Backend PCIe: ED91 fault on hot reset
DCSG01517111 UseIdleSas12G was not set in Hardware even when it was set in the ExtManPage40
DCSG01516427 Fails controller firmware download if detect wrong type
DCSG01510048 Fix the configurable Physical Disk count issue
DCSG01455484 Fix compilation for different targets
DCSG01459879 Improve Copyback disable handling while copyback is in progress on drives
DCSG01072582 SCSI Self-Test Results (0x10) log page not updating status when self-test in progress
DCSG01521501 94xx/95xx PL Spinup: Incorrect write to register to clear the spinup interrupt
DCSG01350001 PL firmware not failing NVMe self-test when already an existing NVMe self-test command is in progress
DCSG01488468 3808N: Cross Reference Architecture Spec Enabled Features with Latest PoC Code
DCSG01476347 Firmware Exception during IO with JBOD Cable Pulls
DCSG01451450 [95xx]: Incorrect slot number management for non-UBM backplanes
DCSG01488467 3916N: Re-enable Full DDF
DCSG01440304 Fix the unwanted blocking of reverting of a hot spare drive after copy back
DCSG01523695 OEM Controller is not booting and stuck during Enclosure Initialization with switch
DCSG01538008 Build all failed on firmware int code
DCSG01525592 VMware OS reported IOMMU Fault iMR controller while running virtual machine IOs VM and controller reset
DCSG01463291 Enhance discovery state machine to complete slot mapping before a drive is inserted.
DCSG01442264 Spinup failed drives (Bad drives) are not seen in LSA/CLI Tool
DCSG01516217 Continuous MCTP command failure with a bad drive in topology leads to controller not being detected through MCTP over I2C on OEM config
DCSG01419594 SLT-Emulator2.0-OOB option all is not showing valid information
DCSG01516607 Maximum spans per virtual drive incorrect
DCSG01454893 MegaRAID 7.25 Beta-Assertion failure in ddf module
DCSG01508452 Observed hang in SAS only and NVMe only mode in 3808N controller after adapter reset.
DCSG01489940 Kill adapter during firmware upgrade and Downgrade with IO.
DCSG01358471 Expander based backplane is not updating page 0xA on drive pull/insertion
DCSG01547639 Firmware: SAS/SATA only firmware for 95xx HBA family
DCSG01467130 [9500] SAS_IO_UNIT_CONTROL/SEND_PRIMITIVE command fails for the phys with PCIe support enabled
DCSG01445968 Update Secure boot Library in Firmware
DCSG01512905 Add new chip entry for 3808N controller.
DCSG01467624 Controller dies after running Snapdump in a loop with 23 nvme drive R5 and IO stress
DCSG01470476 Overnight reading the snapdump OnDemand in a loop, caused iMR Controller not found error
DCSG01454021 Support Drive firmware download without using Host Memory
DCSG01515787 Block the access to disabled Hardware cores on 3808N adapter while dumping pl dbg.
DCSG01516045 zip file created in response to zc megamon command is corrupted
DCSG01151757 SL OOB: NVME response buffer is not displaying user requested size of response buffer.
DCSG01458287 Fix Channel compilation due to OEM changes
DCSG01521548 Updated Firmware to support SCSI to NVMe Translation Spec 1.10
DCSG01487334 Fix snapdump being interrupted due to the time of searching through events
DCSG01533800 NVMe: handle vendor specific failure condition
DCSG01449669 Set jbod shows successful, but jbod does not appear to be created
DCSG01467248 PL Firmware: Bring up of OEM specific EDSFF UBM Backplane.
DCSG01480400 VSES Commands hung during the drive pull test with IOs.
DCSG01462382 Add New Firmware Versions for OEM PartNumbers 15984, 29652, and 25934 to PSoC Catalog Image
DCSG01450318 Controller diag firmware changes from Apps DF: DCSG01444219
DCSG01505532 3808N make firmware changes for new architecture specification updates
DCSG01486559 Virtual SES IOs aren't failed if a UBM I2C transfer error occurs during LED update
DCSG01477125 NVDATA major version was updated to be same as Phase Version
DCSG01551132 NVDATA switch to enable the PDB0B core for 3808 N controller
DCSG01427369 Cable management diagnostic command shows incorrect data for some cables
DCSG01516125 Fix controller setting for support for capacity expansion without adding disks
DCSG01522625 Manual Crash Dump fails when iMR N card is in the test-configuration.
DCSG01443947 [95xx] Reduction in default maximum resource count values in Runtime Configuration Parameters for Enclosures and Expanders
DCSG01588354 Update NVDATA Major Version for Ph30
DCSG01524005 Enhance firmware logging to include PL logs from initial discovery at start of day to address Drive lost across reboots
DCSG01309777 Added duplicate MID protection support to multi-LUN drives
DCSG01446403 LCS work around in PL firmware to be made generic for all models of an OEM specific UBM backplane.
DCSG01481344 NVRAM space to persist information related to certain Redfish Alerts
DCSG01531437 [95xx] NVMe Drive firmware update failed if the drive firmware payload size is more than 2Mb and 32k aligned
DCSG01511337 fix excessive unlocking of secured drive when clearing drive restricting
DCSG01418256 Add support for OEM Backplanes
DCSG01511102 Cache Bypass Modes shown on iMR when there is no write back possible
DCSG01419839 A target reset Task Management to a direct attach SAS drive may not go out to the drive even though PL thinks it has
DCSG01471791 7.26: Firmware found Enclosure exceeds max supported, caused KA on M.2 Ctrl
DCSG01373026 POC: New profile and licensing control & display for the new boot controller
DCSG01524008 Update SCSI to NVMe translation to version 1.10
DCSG01458189 [95xx]: Log sense page 0x15 fails on ACS-5 supported SATA drive.
DCSG01542341 Pulling low power mode NVMe drive causes PL Fault
DCSG01481110 MegaRAID 7.26 Alpha: Data abort during unexpected power loss test with copy back
DCSG01523599 Simultaneous Read/Write Miscompare: Data Read Does Not Match Data Written
DCSG01464478 Add timer module debug functionality in Snapdump module
DCSG01469541 Fix I2C OOB processing null pointer due to I2C reset
DCSG01470940 Snapdump: Add reason codes when clearing
DCSG01480248 Support controller firmware download without using host memory
DCSG01505033 7.27: Drive Pull R1 Hits Exception Handler Called Error
DCSG01506370 When slot is set to non installed firmware does not report enclosure slot bad status
DCSG01435858 Fix the hanging of NVMe passthrough command when request is too big for the controller to handle
DCSG01468284 7.26 PA2: crashdump.txt is taking longer than 15s to generate for ondemand snapdump
DCSG01509009 3808N should block hotspare option in LSA
DCSG01508464 Added Serdes Config Parameters to ExtManPage40
DCSG01454043 Firmware: Production of iMR on 3808N without host memory dependency.
DCSG01453955 Power customization support for SAS3808N board.
DCSG01467889 Non 512 Mutiple ReportZone request cause 0 data transfer but completes successfully.
DCSG01547099 NVMe: a certain NVMe 2.0 device fails to initialize
DCSG01437689 Assertion failure noted in timer module during SATA pass through and IOs test over 2 days
DCSG01471837 Enable Security and controller IO MFC settings for the new boot contoller
DCSG01489595 Fix Ses device not ready handling path
DCSG01377905 Firmware:9540N POC: memory and DDF management changes
DCSG01516095 9500 Series: Fault 0x5805 Invalid Message Frame Index Seen after multiple resets
DCSG01539401 Drives Show up as UGUnsp
DCSG01494307 Firmware: Ensure that IT firmware can not run on the 3808N
DCSG01365348 Series 95xx POC: Remove host memory with SnapDump
DCSG01421204 [95xx] Added feature to override the firmware control of PERST# signal to NVMe drives using NVDATA.
DCSG01531972 Task management failure and assertion seen during hard reset test on JBODs
DCSG01504986 Assertion failure noted in timer module : further root cause of DF: DCSG01437689
DCSG01490785 7.26: 3916N partition failed when create raid 0/1 using NVME drive
DCSG01521495 Updated 'Summary Release Notes' document
DCSG01469813 7.26 PA2: some Snapdump prints flood the uart
DCSG01507596 Firmware crashes when reading the UBM controller information when the UBM controller is in non operational mode.
DCSG01571422 Support external key management over OOB on 9560 with SafeStore and SED drives
DCSG01533403 7.x - OEM specific custom build target environment addition
DCSG01494319 PL support for Direct GPIO LED management.
DCSG01559620 Fix set PCIe lane speed without checking phy validity
DCSG01472315 Long running task for back ground operation are completed to the MC.
DCSG01572396 Snapdump CRC replay debug
DCSG01571116 PL: Firmware failed assertion check for some NVMe drive models
DCSG01520376 Implemented debug function to skip UEFI driver handshake wait
DCSG01589449 Add Firmware Version 23 for PartNumber 29652 to PSoC Catalog Image
DCSG01470015 JBOD volumes link is enabled for Drive resource in RDE
DCSG01602093 Add Firmware Version 25 for PartNumber 29652 to PSoC Catalog Image
DCSG01471998 Added support to send VolumeOffline and VolumeOfflineCleared RDE events when drives get locked and reprovisioned respectively
DCSG01557573 RMC changes for SAS3816
DCSG01542197 Battery Charging Redfish Event is not generating for redfish battery status for Broadcom controllers
DCSG01462821 Blocking of Drive Write Cache for NVMe drives is removed for a particular OEM
DCSG01460306 Removed IML Codes
DCSG01460218 Display empty array for dedicated spare drives and operations for JBOD volumes when RDE GET is issued.
DCSG01571779 Fix 'Static Analysis Tool' reported items in Firmware
DCSG01525592 VMware OS reported IOMMU Fault iMR controller while running virtual machine IOs VM and controller reset
DCSG01503334 Assertion failure seen in Firmware timer module
DCSG01556598 7.27 Beta: drive not seen in storcli after quick pull push with IO and rebuild going on
DCSG01461751 Implement support to update Controller Rates using RDE
DCSG01598659 Add Firmware Version 24 for PartNumber 29652 to PSoC Catalog Image
DCSG01489940 Kill adapter during firmware upgrade and Downgrade with IO.
DCSG01488473 PLDM Firmware Download: Assertion failure in ..\cpu\arm\exceptions.c at line 1046 on triggering QueryDeviceidentifier command in Download state
DCSG01507674 PLDM Type 5 - NVMe drive firmware version is not updated after successful update
DCSG01573644 Wrong Check Added by ER DCSG01558994 for Disabling SAS on 3808N
DCSG01614816 Handle Link isolation on PL initiated task management timeout
DCSG01539651 7.27 3808N: Data abort exception during media error injection test with 4k drives, system can't boot since OS behind controller as well
DCSG01485699 Reduce MegaRaid HDD sequential read performance
DCSG01472892 Send ControllerOK Redfish Event when ControllerDegraded event was logged earlier
DCSG01576996 9540-16i controller is not generated snapdump on OEM server when start of day PL logs capture feature is set
DCSG01462783 PLDM firmware update on drive fails when there are different drive models are connected to the controller
DCSG01588333 OOB Firmware Flash Fails
DCSG01561805 Battery relearn starts/completes in a loop after clearing nvram
DCSG01496206 BatteryOK RDE alert was logged after every AC power cycle of the server
DCSG01473533 Add support for VolumeOffline and VolumeOfflineCleared Redfish Enhanced Alerts
DCSG01521525 Replaced OEM specific max supported physical devices with profile max supported devices in some of the loops
DCSG01615981 RMC Fix for DCSG01598480
DCSG01490067 Implement target ID and sysPD cooldown timer and bypass option for iMR
DCSG01461749 Added support for OEM specific generic backplane
DCSG01466479 Redfish - Implement new Controller Alerts
DCSG01458117 Add support for 'Availability' state set for controller composite sensor
DCSG01460483 RDE - Add new RDE alerts adhering to Storage Device Message Registry 1.1.0
DCSG01556638 Direct attached Lane break test failed on Gen4 NVMe U.2 drive
DCSG01588354 Update NVDATA Major Version for Ph30
DCSG01542190 DriveOfflineCleared Redfish Alert not posted after SED imported with a different Key
DCSG01582911 9540-16i controller firmware sending a lot prints rolling while capturing snapdump
DCSG01601124 NVRAM: Add fields to track phy state to support Link Isolation feature
DCSG01440232 Enhance NVMe Shutdown Timeouts
DCSG01502940 REST client does not display details of copyback operation on drive
DCSG01496212 Predictive failure RDE alert for a drive was logged twice on a single server reboot or controller reset
DCSG01562181 Host boot failure caused a UEFI hang on some systems
DCSG01486632 Firmware: Disk pending defects count support added
DCSG01492588 PLDM firmware update on UBM5 backplane is failing with timeout error
DCSG01464314 During AC Power Cycle Test, I2C Error Occurs
DCSG01576748 Use Direct GPIO LED management if the 3808N Device LED Management policy is set.
DCSG01547753 First time data capture trigger time properties print change
DCSG01523599 Simultaneous Read/Write Miscompare: Data Read Does Not Match Data Written
DCSG01465244 Defect fixes and the associated fixes found during Static Code Analysis
DCSG01458622 Add OEM customizations for Generic Features
DCSG01546055 3808N: 7.27: firmware hitting kill adapter during logical drive check consistency
DCSG01540194 Drive Gets Marked Bad During Reset Test
DCSG01547626 Link Isolation feature support to avoid one fault drive affecting RAID card functionality
DCSG01540844 Foreign drives are not accessible in the RDE client
DCSG01558994 Disable SAS on OEM Boards
DCSG01567599 CRC failure on modules captured under snapdump
DCSG01531576 Redfish - Exception seen with secure foreign drives during reboot
DCSG01603980 VD creation on a particular drive fails with firmware fault
DCSG01548367 Set batterywarning succeeds on narrow controller which does not support battery
DCSG01544525 Request for additional information about host PCIe from OOB
DCSG01569025 MegaRAID 7.28: firmware assertion in timer module while running MCTP out of band communication
DCSG01531972 Task management failure and assertion seen during hard reset test on JBODs
DCSG01480038 RDE - Incorrect HTTP error code displayed for Redfish CREATE operation without JSON body
DCSG01571660 Enable PCD eFuse Runtime Check for 3808N
DCSG01528863 Drives are marked as Unconfigured Bad in 9540 controller during the hot-plug test.
DCSG01570991 Help commands being shown instead of useful information in start of day snapdump
DCSG01571899 Build all failed on firmware int code
DCSG01574223 Commands Failed on NVMe Drives
DCSG01552620 Fix unwanted warning message of debug flag
DCSG01507594 Secured spanned Virtual disk creation is successful.
DCSG01580987 Fix drive firmware download timeout due to slow OOB download
DCSG01535249 [IN776543]Improper product name for UBM5 BP
DCSG01558739 MegaRaid 7.27 Program - New release/build target addition for OEM specific program
DCSG01587543 MCTP discovery : Set EID request timeout
DCSG01561751 PLDM Flashing Exception
DCSG00013257 HW Workaround:HW_SETTINGS_CHANGE : PCIe PHY LF setting should be changed from 16 to 15
DCSG00108561 Clean up SBR Build Tools
DCSG00068041 SBR Build date and time corrected
DCSG01335479 Update Source to Latest and Fix Uninitialized Variable
DCSG01618357 Updated OEM NVDATA
DCSG01568048 OEM Needs Multi-VSES Enabled in NVDATA via SubOEMID
DCSG01574298 Enable Feature for OEM
DCSG01559023 Created new OEM HWBIC.
DCSG01227412 M.2 controller does not report slot numbers for two drives properly.
DCSG01223238 Setting suboemID to 0xC causes the controller to fault
DCSG01574292 Updated OEM HWBICs
DCSG01574297 Remove PCIe setting from OEM HWBIC.
DCSG01526064 9580-8i8e NVMe drives not detected on internal ports
DCSG01083355 MegaRAID 9561-16i
DCSG01493657 Incorrect Slot Numbers on M.2 Controllers
DCSG00026388 Fix storcli Output Compare for Ventura vs Aero
DCSG00026403 Fix HWBIC BSP CBB Names to Reflect EVT vs DVT
DCSG01490624 Update OEM HWBIC
DCSG01547628 Individual control of drive fault LEDs for direct attached drives in boot solution
DCSG01043351 Aero MR: allow user to ON/OFF ALARM using StorCLI
DCSG00041568 not applicable
DCSG01571423 Enable Feature for OEM
DCSG01177800 ReleaseOrderPkg:DCSG01176818 failed to include the rebranded new type of 9561-xx
DCSG01621422 Modified OEM HWBIC Setting
-
Broadcom 95xx最新固件下载 2023-01-02 StorCLI version 7.2307.0000.0000 or later can be used to upgrade the PSoC component.Controller FW package 52.20.0-4341 or later must be first installed on the adapter.Due to hardware changes on the below adapters, after upgrading to after upgrading iMR/HBA to any MR 7.22 (52.22.x-xxxx) orlater package, downgrading to MR 7.21 or older (52.21.x-xxxx, 52.20.x-xxxx, etc.) is not allowed.*****************************************************************************************************************************************************PLEASE READ THESE GUIDELINES FOR HBA CONTROLLERS (9500-xx)*********************************************************************************************************************************************************************StorCLI version 7.2307.0000.0000 or later can be used to upgrade the PSoC component.Controller FW package P24 24.00.00.00 or later must be first installed on the adapter.******************************************************************************************************************************************************************************************************************************************************======================Supported Controllers:======================MegaRAID 9560-8iMegaRAID 9560-16iMegaRAID 9580-8i8eMegaRAID 9562-16iMegaRAID 9540-8iMegaRAID 9540-16iHBA 9500-8iHBA 9500-16iHBA 9500-8eHBA 9500-16eHBA 9502-16iComponent:=========PSoC Catalog Firmware v1.25 (DCSG01375926)Release date: 12/05/2022Version Numbers:===============PBLP_HBA_P4_Version_HW:1.00_FW:10.00_PN:14790PBLP_HBA_P4S423_Version_HW:1.00_FW:10.00_PN:14798PBLP_HBA_P4S443_Version_HW:1.00_FW:10.00_PN:06021PBLP_RAID_P5_Version_HW:3.00_FW:27.00_PN:15987PBLP_RAID_P5Init_Version_HW:3.00_FW:27.00_PN:12345PBLP_RAID_P5OCP_Version_HW:8.00_FW:3.00_PN:25731PBLP_RAID_P6_Version_HW:10.00_FW:18.00_PN:29211PBLP_RAID_P6Travis_Version_HW:11.00_FW:18.00_PN:29651